Part Number Hot Search : 
29F1G08 AAT117 AD7542JN AAT117 4761A TC427 M1610 25PPC405
Product Description
Full Text Search
 

To Download G2RV-SR500-APDC12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 g2rv-sr g3rv-sr common accessories common precautions glob a l s t an dard size, low profile slim (6.2 mm width) i/o relays ? 25% lower profile than conventional product s, contributing to a smaller c ontrol panel. ? push-in plus terminal blocks reduce wiring work by 60%* compared to conventional screw terminals. ? ?hand-free? structure that holds an inserted flat-blade screwdriver to achieve easier wiring work for stranded wires. ? electromechanical relays (g2rv-sr) and solid state relays (g3rv-sr) are available. ? screw terminal terminal block models are available. ? plug-in terminal has strong mechanical p ins that do not bend . * according to o mron act ual measurement dat a from november 2015. slim i/o relay types g2rv-sr series mounted relay: electromagnetic relay ...... from page 2 g3rv-sr series mounted relay: solid state relay ................ from page 10 common matter common precautions ................................................................ from page 20 common accessories (order separately)................................. page 24 fo r the recent inf o rmat ion on models t hat hav e been certified fo r safety standards, refer t o y our o mron website. g3rv-sr: g2rv-sr: refer to safety precautions on page 20. slim i/o relays g2rv-sr/g3rv-sr
g2rv-sr g3rv-sr common accessories common precautions 2 slim electromechanical i/o relay g2rv-sr g lobal standard size, low profile, slim ( 6.2 mm width) i/o relay ? 25% lower pr ofile than conventional products, contributing to a smaller control panel. ? opening and closing ability with one pole 6 a slim shape. ? micro load products for one pole 50 ma using go ld-plated contacts for small load switching also available. ? since g2rv has a transparent case, confirming the state of the contact with the naked eye is possible. ? screw terminal terminal block models are available. ? p lug-in type terminal has strong mechanical pins that do not bend. features for the recent information on models that have been certified for safety standards, refer to your omron website. refer to safety precautions on page 20. transparent case relay contact release lever plug-in terminal 90 mm 80 mm terminal has strong mechanical pins that do not bend. easy confirmation of the situation relay easily fixed/removed pat terminal x 5 ? p u sh-in ? scre w mechanical indicator release le v er operation display led (socket section) ? operation v erification w hich is linked to the contact standard model/micro load with latchin g lever (test switch) latching le v er (test s w itch) ? circ u it check operation confirmation, red u cing the inspection effort latching le v er (test s w itch) protecti v e co v er (released state) push-in plus terminal block short b ar insertion holes terminal (insertion) hole release hole protecti v e co v er (locked condition) "foreign matter intr u sion pre v ention str u ct u re" "malf u nction pre v ention stopper"
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 3 model number structure model number legend ordering information terminal (wire connection) classification latching lever (test switch) rated input voltage (v) model push-in plus terminal standard no dc 12 g2rv-sr500 dc12 24 g2rv-sr500 dc24 ac/dc 24 g2rv-sr500 ac/dc24 48 g2rv-sr500 ac/dc48 ac 100 g2rv-sr500 ac100 110 g2rv-sr500 ac110 200 g2rv-sr500 ac200 230 g2rv-sr500 ac230 yes dc 24 g2rv-sr501 dc24 ac/dc 24 g2rv-sr501 ac/dc24 microloads no dc 12 g2rv-sr500-ap dc12 24 g2rv-sr500-ap dc24 ac/dc 24 g2rv-sr500-ap ac/dc24 48 g2rv-sr500-ap ac/dc48 ac 100 g2rv-sr500-ap ac100 110 g2rv-sr500-ap ac110 200 g2rv-sr500-ap ac200 230 g2rv-sr500-ap ac230 screw terminal standard no dc 12 g2rv-sr700 dc12 24 g2rv-sr700 dc24 ac/dc 24 g2rv-sr700 ac/dc24 48 g2rv-sr700 ac/dc48 ac 100 g2rv-sr700 ac100 110 g2rv-sr700 ac110 200 g2rv-sr700 ac200 230 g2rv-sr700 ac230 yes dc 24 g2rv-sr701 dc24 ac/dc 24 g2rv-sr701 ac/dc24 microloads no dc 12 g2rv-sr700-ap dc12 24 g2rv-sr700-ap dc24 ac/dc 24 g2rv-sr700-ap ac/dc24 48 g2rv-sr700-ap ac/dc48 ac 100 g2rv-sr700-ap ac100 110 g2rv-sr700-ap ac110 200 g2rv-sr700-ap ac200 230 g2rv-sr700-ap ac230 g2rv-sr @@ @ - @ @ (1) (2) (3) (5) (6) (4) (1) basic model name g2rv: slim i/o relay (2) su b type sr: slim relay + integrated low profile socket (3) terminal (wire connection) 50: push-in plus terminal 70: screw terminal (4) latching lever (test switch) 0: without latching lever 1: with latching lever (5) contact structure blank: standard ap: microloads (6) rated input voltage 12, 24 vdc 24, 48 vac/vc 100, 110, 200, 230 vac note: solid wire cannot be used for push-in plus terminal type. mak e sure to use stranded wire or stranded wire with ferrules.
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 4 relay for maintenance model number legend list of models (1) no. of poles 1: 1 pole (2) t erminal s: plug-in (3) l atching lever (test switch) blank: without latching lever i : with latching lever (4) co ntact material blank: silver alloy ap: silver alloy + gold plate (5) types of relay for exchange g: g2rv-sr series equipped relay (6) rated coil voltage number: 11, 21, 48 vdc (1) (2) (3) (5) (6) (4) g2rv-1 - s @ - @ - g @ g2rv-1-si-g g2rv-1-s-g(-ap) type latching lever (test switch) rated coil voltage (v) model applicable model standard no dc 11 g2rv-1-s-g dc11 g2rv-sr700/500 dc12v 21 g2rv-1-s-g dc21 g2rv-sr700/500 dc24v g2rv-sr700/500 ac/dc24v 48 g2rv-1-s-g dc48 g2rv-sr700/500 ac/dc48v g2rv-sr700/500 ac100v g2rv-sr700/500 ac110v g2rv-sr700/500 ac200v g2rv-sr700/500 ac230v yes dc 21 g2rv-1-si-g dc21 g2rv-sr701/501 dc24v g2rv-sr701/501 ac/dc24v microload no dc 11 g2rv-1-s-ap-g dc11 g2rv-sr700/500-ap dc12v 21 g2rv-1-s-ap-g dc21 g2rv-sr700/500-ap dc24v g2rv-sr700/500-ap ac/dc24v 48 g2rv-1-s-ap-g dc48 g2rv-sr700/500-ap ac/dc48v g2rv-sr700/500-ap ac100v g2rv-sr700/500-ap ac110v g2rv-sr700/500-ap ac200v g2rv-sr700/500-ap ac230v
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 5 specifications ratings coil ratings note: the operating characteristics are measured at ambient temperature of 23c. * operating voltage will be 85% max. for upside down mounting. contact ratings *1. p level: 60 =0.110 -6 /times this value is the value in switching frequency 120 operations/min. *2. if the gold plating layer is destroyed, the number will be t he same as the standard type. characteristics note: above values are initial values. * value is at ambient temperature of 23c. rated input voltage rated current operation voltage r elease voltage power consumption maximum allowable voltage ac dc percentage of the rated voltage ac (va) dc (mw) percentage of the rated voltage 50 hz 60 hz 12 vdc ? ? 27.2 ma 80% max.* 10% min. ? approx. 300 mw 110% 24 vdc ? ? 13.3 ma ? approx. 300 mw 24 vac/vdc 21.1 ma 22.5 ma 13.0 ma approx. 0.5 va approx. 300 mw 48 vac/vdc 8.5 ma 9.0 ma 5.2 ma approx. 0.4 va approx. 250 mw 100 vac 7.1 ma 7.5 ma ? approx. 0.8 va ? 110 vac 7.1 ma 7.5 ma ? approx. 0.8 va ? 200 vac 7.2 ma 7.9 ma ? approx. 1.7 va ? 230 vac 7.3 ma 7.9 ma ? approx. 1.7 va ? item standard (g2rv-sr700, 500, 701, 501) for microloads (g2rv-sr700-ap, 500-ap) *2 contact configuration spdt load resistive load (cos =1) inductive load (cos =0.4, l/r=7ms) resistive load (cos =1) rated load 6 a at 250 vac 6 a at 30 vdc 2.5 a at 250 vac 2 a at 30 vdc 50 ma at 30 vac 50 ma at 36 vdc rated carry current 6 a 50 ma maximum switching voltage 440 vac, 125 vdc 30 vac, 36 vdc maximum switching current 6 a 50 ma maximum switching power 1,500 va 180 w 500 va 60 w ? failure rate p value (reference value) *1 10 ma at 5 vdc 1 ma at 100 mvdc item standard (g2rv-sr700, 500, 701, 501) for microloads (g2rv-sr700-ap, 500-ap) contact resistance * 100 m max. operate (set) time * 20 ms max. release time * ac, ac/dc: 40 ms max. dc: 20 ms max. maximum operating frequency mechanical: 18,000 operations/h electrical: 1,800 operations/h (rated load) insulation resistance 1,000 m min. (at 500 vdc) dielectric strength between coil and contacts: 4,000vac 50/60 hz 1 min contact between the same polarity: 1,000 vac 50/60 hz 1 min vibration resistance destruction: 10 to 55 to 10 hz, single amplitude 0.50 mm (double amplitude 1.0 mm) malfunction: 10 to 55 to 10 hz, single amplitude 0.50 mm (double amplitude 1.0 mm) shock resistance destruction: 1,000 m/s 2 malfunction: energized 200m/s 2 , non-energized 100m/s 2 endurance * mechanical 5,000,000 operations min. electrical no contact: 70,000 operations min. nc contact: 50,000 operations min. 5,000,000 operations min. ambient operating temperature operating: ?40 to +55c (with no icing or condensation) ambient operating humidity operating: 5 to 85% rh weight approx. 30 g contact material ag alloy ag alloy + au plating
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 6 approved standards ul508 (file no.e41643) * if the load voltage exceeds 250 vac, please attach with a spacing of 12 mm min., or use a separate plate (xw5z-ep12). vde (en 61810-1) * if the load voltage exceeds 250 vac, please attach with a spacing of 12 mm min., or use a separate plate (xw5z-ep12). engineering data endurance curve (n.o. side) switching capacity of dc resistive load model no. of poles operation coil ratings contact ratings operations g2rv-sr series spdt 12 to 48 vdc 24 to 230 vac 6 a at 250 vac (resistive load) 6 a at 30 vdc (resistive load) 2 a at 400 vac (resistive load)* 6,000 12 mm 12 mm 12 mm model no. of poles operation coil ratings contact ratings operations g2rv-sr series spdt 12, 24 vdc 24, 48 vac/vdc 100, 110, 200, 230 vac 6 a at 250 vac (resistive load) 6 a at 30 vdc (resistive load) 2 a at 400 vac (resistive load)* 50,000 50,000 6,000 12 mm 12 mm 12 mm 10 100 1000 024 opening and closing c urrent (a) 6 250 vac resistive load 30 vdc resistive load 30 vdc resistive load 250 vac resistive load numb er of operations (x 10 3 operations) 0.1 1.0 10.0 20 60 100 140 180 220 dc switching voltage (v) dc breaking current (a)
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 7 dimensions (unit: mm) slim i/o relay + socket push-in plus terminal block 65.89 51.72 35.25 18.78 35.25 74.5 18.78 35.3 78.77 (5.05) (5.05) 59.71 3.4 78 max. 90 max. 6.2 max. a1 a2 12 14 11 input circuit input circuit 11 14 12 a2 a1 g2rv g2rv * : diode bridge other voltage : light emitting diode terminal arrangement/internal connection diagram (t op view) 24 vdc 12 a2 14 11 a1 input circuit g2rv 12 vdc models without latching lever (without test switch) g2rv-sr500 g2rv-sr500-ap 65.89 51.72 35.25 18.78 35.25 77.5 18.78 35.3 78.77 (5.05) (5.05) 59.71 3.4 81 max. 90 max. 6.2 max. 12 a2 14 11 a1 a1 a2 12 14 11 11 14 12 a2 a1 g2rv g2rv g2rv input circuit input circuit input circuit * : diode bridge other voltage : light emitting diode terminal arrangement/internal connection diagram (t op view) 12 vdc 24 vdc models with latching lever (with test switch) g2rv-sr501
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 8 screw terminal 65.89 51.65 35.18 18.71 18.71 35.18 74.5 (5.05) (5.05) 35.3 78.77 56.2 3.4 78 max. 6.2 max. 90 max. 11 14 12 a2 a1 a1 11 14 a2 12 input circuit g2rv input circuit g2rv * : diode bridge other voltage : light emitting diode terminal arrangement/internal connection diagram (t op view) 12 vdc a1 a2 12 14 11 input circuit g2rv 24 vdc models without latching lever (without test switch) g2rv-sr700 g2rv-sr700-ap 65.89 51.65 35.18 18.71 18.71 35.18 77.5 (5.05) (5.05) 35.3 78.77 56.2 3.4 81 max. 6.2 max. 90 max. a1 a2 12 14 11 11 14 12 a2 a1 a1 11 14 a2 12 g2rv g2rv g2rv input circuit input circuit input circuit * : diode bridge other voltage : light emitting diode terminal arrangement/internal connection diagram (t op view) 12 vdc 24 vdc models with latching lever (with test switch) g2rv-sr701
g2rv-sr g2rv-sr g3rv-sr common accessories common precautions 9 relay for maintenance a2 a1 12 11 14 30.5 max. 3.5 0.5 2.4 1.8 5.2 max. 5.04 5.04 3 22 33 max. 16.2 terminal arrangement/ internal connection diagram (top view) (input circuit) models without latching lever g2rv-1-s-g g2rv-1-s-ap-g models with latching lever (test switch) g2rv-1-si-g a2 a1 12 11 14 30.5 max. 5.2 max. 1.8 0.5 2.4 5.0 4 5.04 3 22 36 max. 16.2 3.5 terminal arrangement/ internal connection diagram (top view) (input circuit)
10 g2rv-sr g3rv-sr common accessories common precautions slim i/o solid state relay g3rv-sr gl ob a l s t an dard size, low profile, slim (6.2 mm width) i/o solid state relay. ? 25% lower profile than conventional products, contributing to a smaller control panel. ? optimal slim, high frequency, high-speed opening and closing ssr (solid state relay). ? slim shape with a switching c apacity up to 3 a (dc), and 2 a (ac). ? because mosfet is used for the outlet element for the dc load, opening and closing load of 100 a to 3 a is possible. ? check operating status at a glance with the operating display led. ? mounted i/o ssr (solid-state relay) uses plug-in terminals with strong mechanical pins that do not bend. features for the recent information on models that have been certified for safety standards, refer to your omron website. refer to safety precautions on page 20. terminal x 5 ? push-in ? screw release lever operation display led (socket section) operation display led (ssr section) push-in plus terminal block short bar insertion holes terminal (insertion) hole release hole release lever 90 mm 80 mm relay easily fixed/removed plug-in terminal terminal has strong mechanical pins that do not bend.
g2rv-sr g3rv-sr common accessories common precautions g3rv-sr 11 model number structure model number legend (1) basi c model name g3rv : slim i/o solid state relay (2) s ub type sr: slim solid relay + integrated low profile socket (3) te rminal (wire connection) 500: push-in plus terminal 700: screw terminal (4) o utput voltage specification a : ac output (triac) zero cross function available al : ac output (triac) zero cross function not available d : dc output (mos fet) (5) rated voltage input 12, 24 vdc 24, 48 vac/v dc 100, 110, 200, 230 vac g3rv-sr @ @ @ - @ @ (1) (2) (3) (4) (5)
g3rv-sr 12 g2rv-sr g3rv-sr common accessories common precautions ordering information terminal (wire connection) applicable output load zero cross function rated input voltage (v) model push-in plus terminal dc load ? dc 12 g3rv-sr500-d dc12 24 g3rv-sr500-d dc24 ac/dc 24 g3rv-sr500-d ac/dc24 48 g3rv-sr500-d ac/dc48 ac 100 g3rv-sr500-d ac100 110 g3rv-sr500-d ac110 200 g3rv-sr500-d ac200 230 g3rv-sr500-d ac230 ac load yes dc 12 g3rv-sr500-a dc12 24 g3rv-sr500-a dc24 ac/dc 24 g3rv-sr500-a ac/dc24 48 g3rv-sr500-a ac/dc48 ac 100 g3rv-sr500-a ac100 110 g3rv-sr500-a ac110 200 g3rv-sr500-a ac200 230 g3rv-sr500-a ac230 no dc 12 g3rv-sr500-al dc12 24 g3rv-sr500-al dc24 ac/dc 24 g3rv-sr500-al ac/dc24 48 g3rv-sr500-al ac/dc48 ac 100 g3rv-sr500-al ac100 110 g3rv-sr500-al ac110 200 g3rv-sr500-al ac200 230 g3rv-sr500-al ac230 screw terminal dc load ? dc 12 g3rv-sr700-d dc12 24 g3rv-sr700-d dc24 ac/dc 24 g3rv-sr700-d ac/dc24 48 g3rv-sr700-d ac/dc48 ac 100 g3rv-sr700-d ac100 110 g3rv-sr700-d ac110 200 g3rv-sr700-d ac200 230 g3rv-sr700-d ac230 ac load yes dc 12 g3rv-sr700-a dc12 24 g3rv-sr700-a dc24 ac/dc 24 g3rv-sr700-a ac/dc24 48 g3rv-sr700-a ac/dc48 ac 100 g3rv-sr700-a ac100 110 g3rv-sr700-a ac110 200 g 3rv-sr700-a ac200 230 g3rv-sr700-a ac230 no dc 12 g3rv-sr700-al dc12 24 g3rv-sr700-al dc24 ac/dc 24 g3rv-sr700-al ac/dc24 48 g3rv-sr700-al ac/dc48 ac 100 g3rv-sr700-al ac100 110 g3rv-sr700-al ac110 200 g3rv-sr700-al ac200 230 g3rv-sr700-al ac230 note: solid wire cannot be used for push-in plus terminal type. make sure to use stranded wire or stranded wire with ferrules .
g3rv-sr 13 g2rv-sr g3rv-sr common accessories common precautions solid state relay for maintenance model number legend list of models * different depending on the ambient temperature. for more details, refer to load current vs. ambient rated temperature on page 16. (1) o utput voltag e sp ecification d: dc output 2: ac output (2) rated current 02: ac output 2 a 03: dc output 3 a (3) t erminal s: plug-in type (4) z ero cross functions blank: zero cross function available l: zero cross function not available (5) rated input voltage number: 12, 24, 48 vdc g3rv- @ @ s @ @ (1) (2) (3) (4) (5) insulation method operation display output (ssr) zero cross function rated output load * rated input voltage (socket) model applicable model photo- triac yes (green) ac yes 2 a (at 100 to 240 vac) 12 vdc g3rv-202s dc12 g3rv-sr700/500-a dc12v 24 vdc g3rv-202s dc24 g3rv-sr700/500-a dc24v 24 vac/vdc g3rv-sr700/500-a ac/dc24v 48 vac/vdc g3rv-202s dc48 g3rv-sr700/500-a ac/dc48v 100 vac g3rv-sr700/500-a ac100v 110 vac g3rv-sr700/500-a ac110v 200 vac g3rv-sr700/500-a ac200v 230 vac g3rv-sr700/500-a ac230v no 12 vdc g3rv-202sl dc12 g3rv-sr700/500-al dc12v 24 vdc g3rv-202sl dc24 g3rv-sr700/500-al dc24v 24 vac/vdc g3rv-sr700/500-al ac/dc24v 48 vac/vdc g3rv-202sl dc48 g3rv-sr700/500-al ac/dc48v 100 vac g3rv-sr700/500-al ac100v 110 vac g3rv-sr700/500-al ac110v 200 vac g3rv-sr700/500-al ac200v 230 vac g3rv-sr700/500-al ac230v photo- voltage coupler dc ? 3 a (at 5 to 24 vdc) 12 vdc g3rv-d03sl dc12 g3rv-sr700/500-d dc12v 24 vdc g3rv-d03sl dc24 g3rv-sr700/500-d dc24v 24 vac/vdc g3rv-sr700/500-d ac/dc24v 48 vac/vdc g3rv-d03sl dc48 g3rv-sr700/500-d ac/dc48v 100 vac g3rv-sr700/500-d ac100v 110 vac g3rv-sr700/500-d ac110v 200 vac g3rv-sr700/500-d ac200v 230 vac g3rv-sr700/500-d ac230v
g3rv-sr 14 g2rv-sr g3rv-sr common accessories common precautions specifications rating (ambient temperature 25c) input g3rv-sr700/500-a series g3rv-sr700/500-al series g3rv-sr700/500-d series output rated input voltage rated current operation voltage r elease voltage input voltage ac dc percentage of the rated voltage 50 hz 60 hz 12 vdc ? ? 15 ma 10.8 v max. 1 v min. 10% 24 vdc ? ? 12 ma 21.6 v max. 24 vac/vdc 20 ma 21 ma 11 ma 21.6 v max. 48 vac/vdc 10 ma 11 ma 6 ma 43.2 v max. 100 vac 7.5 ma 7.5 ma ? 90 v max. 110 vac 7.5 ma 7.7 ma ? 99 v max. 200 vac 7.3 ma 8.6 ma ? 180 v max. 230 vac 7.3 ma 8.6 ma ? 207 v max. rated input voltage rated current input voltage ac dc percentage of the rated voltage 50 hz 60 hz 12 vdc ? ? 15 ma 1 v min. 10% 24 vdc ? ? 12 ma 24 vac/vdc 20 ma 21 ma 11 ma 48 vac/vdc 10 ma 11 ma 6 ma 100 vac 7.5 ma 7.7 ma ? 110 vac 7.5 ma 7.7 ma ? 200 vac 7.3 ma 8.6 ma ? 230 vac 7.3 ma 8.6 ma ? rated input voltage rated current input voltage ac dc percentage of the rated voltage 50 hz 60 hz 12 vdc ? ? 8 ma 1 v min. 10% 24 vdc ? ? 4.5 ma 24 vac/vdc 10.7 ma 11.1 ma 4.3 ma 48 vac/vdc 9.6 ma 10.2 ma 6 ma 100 vac 6.8 ma 7.2 ma ? 110 vac 6.8 ma 7.2 ma ? 200 vac 6.8 ma 8.1 ma ? 230 vac 6.8 ma 8.1 ma ? item g3rv-sr700/500-a(l) g3rv-sr700/500-d rated load voltage 100 to 240 vac (50/60 hz) 5 to 24 vdc load voltage range 75 to 264 vac (50/60 hz) 3 to 26.4 vdc load current 0.1 to 2 a (ambient temperature=25c) 100 a to 3 a (ambient temperature=25c) inrush current resistance 30 a (60 hz, 1 cycle) 30 a (60 hz, 1 cycle) permissible l 2 t; joule integral value (reference value) 15a 2 s9 a 2 s applied load capacity 400 w (output voltage: 200 vac) 72 w (output voltage: 24 vdc) o per ation voltage r elease voltage operation voltage r elease voltage 10.8 v max. 21.6 v max. 21.6 v max. 43.2 v max. 90 v max. 99 v max. 180 v max. 207 v max. 10.8 v max. 21.6 v max. 21.6 v max. 43.2 v max. 90 v max. 99 v max. 180 v max. 207 v max.
g3rv-sr 15 g2rv-sr g3rv-sr common accessories common precautions characteristics approved standards ul 508 (file no.e64562) tv 62314 item g3rv-sr700/500-a g3rv-sr700/500-al g3rv-sr700/500-d operate time 1/2 cycle of load power supply +1 ms max. 3 ms max. 6 ms max. release time 60 ms max. 60 ms max. 60 ms max. output on voltage drop 1.6 v (rms) max. leakage current 5 ma max. (at 200 vac, 50/60 hz) 10 a max. (at 24 vdc) insulation resistance 100 m min. (at 500 vdc) dielectric strength between input and output 2,500 vac 50/60 hz 1 min vibration resistance malfunction: 10 to 55 to 10 hz double amplitude 0.70 mm shock resistance 300m/s 2 ambient operating temperature storage: ?30 to +100c (with no icing or no condensation) operating: ?30 to +55c (with no icing or no condensation) ambient operating humidity 45 to 85% rh weight approx. 38 g pollution degree 2 the degree of protection by iec60529 ip20 rated impulse dielectric strength 4.0 kv/ iii load category lc-a dc-12 overload current profile 1.5ie 1.1ue 5s on, 10s off, 10 cycles rated insulation voltage 240 v model input ratings contact ratings g3rv-sr700/500-d series 12, 24 vdc 24, 48 vac/vdc 100, 110, 200, 230 vac 24 vdc 3 a (resistive load) at 25c g3rv-sr700/500-a(l) series 12, 24 vdc 24, 48 vac/dc 100, 110, 200, 230 vac 240 vac 2 a (resistive load) at 25c model input ratings contact ratings g3rv-sr700/500-d series 12, 24 vdc 24, 48 vac/vdc 100, 110, 200, 230 vac 24 vdc 3 a (resistive load) g3rv-sr700/500-a(l) series 12, 24 vdc 24, 48 vac/vdc 100, 110, 200, 230 vac 240 vac 2 a (resistive load) output on resistance ? ? 0.3 max. (at 24 vdc)
g3rv-sr 16 g2rv-sr g3rv-sr common accessories common precautions engineering data load current vs. ambient rated temperature g3rv-sr700/500-a(l) series g3rv-sr700/500-d series inrush current resistance: non-repetitive keep the inrush current to below the inrush current resistance value (i.e., below the broken li ne) if it occurs repetitively. product mounting spacing 10 mm (separate mounting) close mounting (up to 5 units *) product mounting spacing 10 mm (separate mounting) close mounting (up to 5 units *) * when five or more are installed, install with 10 mm space bet ween each. f or details, please refer to mounting on page 23. g3rv-sr700/500-a(l) series g3rv-sr700/500-d series ?30 ?20 0 40 60 80 100 55 ambient temperature (c) 5 4 3 2 1 0 load current (a) 20 25 ?30 ?20 0.2 0406080100 55 5 4 3 2 1 0 20 25 ambient temperature (c) load current (a) ?30 ?20 0 40 60 80 100 55 5 4 3 2 1 0 20 25 ambient temperature (c) load current (a) ?30 ?20 0.5 0202540 6080100 55 5 4 3 2 1 0 ambient temperature (c) load current (a) 40 35 30 25 20 15 10 5 0 inrush current (a.peak) 10 30 50 100 300 500 1,000 3,000 5,000 energized time (ms) 40 35 30 25 20 15 10 5 0 10 30 50 100 300 500 1,000 3,000 5,000 inrush current (a.peak) energized time (ms)
g2rv-sr g3rv-sr common accessories common precautions g3rv-sr 17 dimensions (unit: mm) solid state relay + socket push-in plus terminal block g3rv-sr500 a2 a1 a1 a2 12 14 13 12 14 13 input circuit input circuit * : diode bridge : light emitting diode a1 13 14 a2 12 input circuit a2? a1+ 13 (+) 14 (?) g3rv input output a2? a1+ 13 (+) 14 (?) g3rv input output the information in parentheses in f or a dc output. the information in parentheses in for a dc output. a2? a1+ 13 (+) 14 (?) g3rv input output the information in parentheses in f or a dc output. 65.89 51.72 35.25 18.78 35.25 74.5 18.78 35.3 78.77 (5.05) (5.05) 59.71 3.4 78 max. 90 max. 6.2 max. 12 vdc 24 vdc terminal arrangement/ internal connection diagram (top view) other voltage
g3rv-sr 18 g2rv-sr g3rv-sr common accessories common precautions screw terminal g3rv-sr700 a2 a1 a1 a2 12 14 13 12 14 13 input circuit * : diode bridge input circuit : light emitting diode a1 13 14 a2 12 input circuit a2? a1+ 13 (+) 14 (?) g3rv input output a2? a1+ 13 (+) 14 (?) g3rv input output the information in parentheses in f or a dc output. the information in parentheses in for a dc output. a2? a1+ 13 (+) 14 (?) g3rv input output the information in parentheses in f or a dc output. 12 vdc 24 vdc terminal arrangement/ internal connection diagram (top view) 65.89 51.65 35.18 18.71 18.71 35.18 74.5 (5.05) (5.05) 35.3 78.77 56.2 3.4 78 max. 6.2 max. 90 max. other voltage
g3rv-sr 19 g2rv-sr g3rv-sr common accessories common precautions solid state relay for maintenance g3rv-d03sl g3rv-202s(l) terminal arrangement/ internal connection diagram (top view) g3rv-d03sl (input circuit) g3rv-202s(l) (input circuit) 33 max. 30.5 max. 2.4 15.8 5.2 max. 3.5 1.8 5.04 3 22 14 13 a1 a2 input load 14 13 a1 a2 input load
g2rv-sr/g3rv-sr 20 g2rv-sr g3rv-sr common accessories common precautions safety precautions be sure to read the safety precautions for all relays in the website at the following url: www.omron247.com. format of warning indications meaning of graphic symbols for ensuring product safety ensure that the socket is not charged during wiring and maintenance. not doing so may result in electric shock. do not touch the terminal section of the g2rv-sr or the surrounding area while the power is being supplied. doing so may result in electric shock. minor electrical shock may occasionally occur. do not touch the g3rv terminal section (i.e., current carrying parts) while the power is being supplied. the g3rv may rupture if short-circuit current flows. as protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. minor electrical shock may occasionally occur. do not touch the main circuit terminals on the g3rv immediately after the power supply has been turned off. shock may result due to the electrical charge stored in the built-in snubber circuit. note: g3rv-202s(l), g3rv-sr500/700-a(l) series models only minor burns may occasionally occur. do not touch the g3rv or the heat sink while the power is being supplied or immediately after the power supply has been turned off. the g3rv becomes extremely hot. provide a space of at least 3 mm between the g2rv- sr and ground. not doing so may result in a ground fault. transport ? do not use the product if it has been dropped on the ground. dropping the product may adver sely affect performance. ? do not drop the product or subject it to abnormal vibration or shock during transportation or mounting. doing so may result in deterioration of performance, malfunction, or failure. ? do not transport the product without it being packaged. doing so may result in damage, malfunction, or failure. ? do not transport the g3rv under the following conditions. doing so may result in damage, malfunction, or deterioration of performance characteristics. ? high temperature, high humidity conditions ? conditions such as temperature change that causes rapid condensation ? condition where it is not packaged operating and storage environments ? do not use or store the product in the following locations. doing so may result in damage, malfunction, or deterioration of performance characteristics. ? do not store in locations subject to ambient storage temperatures outside the range ?40 to 70c (for g2rv) and outside the range ?30 to 100c (for g3rv). ? locations subject to relative humidity outside the range 5% to 85% (for g2rv) and outside the range 45% to 85% (for g3rv). ? locations subject to high temperature or high humidity. ? conditions such as temperature change that causes rapid condensation ?l ocations where corrosive gases or flammable gases are present ? location where rainwater or water droplets gets splashed ? location with splashes of wa ter, oil, and chemicals, etc. ? locations with much dust, salt, and iron powder ? location with blockers ? where static electricity or noise occurs ? where strong electromagnetic field is generated ? where there is a risk of exposure to radioactivity ? do not use or store sockets in environments that contain silicone gas, sulfidizing gas (e.g., so 2 or h 2 s), or organic gas, or near materials that contain silicone. doi ng so may cause the contacts to be unstable or to fail. handling ? keep the g3rv well ventilated. there is a risk of short-circuiting or burning due to g3rv overheating. warning indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. additionally, there may be significant property damage. caution indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. precautions for safe use indicates supplementary comments on what to do or avoid doing, to use the product safety. precautions for correct use includes operating precautions to ensure that the product will operate properly and that performance and functions will not be adversely affected. indicates the possibility of electric shock under specific conditions. used for general caution, warning, or danger precautions for which there is no specified symbol. (this symbol is also used as the alerting symbol, but shall not be used in this meaning on the product.) indicates the possibility of explosion or rupture under specific conditions. indicates the possibility of injuries by high temperature under specific conditions. warning caution precautions for safe use
g2rv-sr/g3rv-sr 21 g2rv-sr g3rv-sr common accessories common precautions mounting ? bef ore you start wiring, please make sure that the socket is securely attached to the mounting rail. if the socket is uns table, it may come loose with a risk of injury towards the workers. ? please insert the flat-blade screwdriver to the bottom of the hole. if you do not insert the flat-blade screwdriver correctly, the cable will not be connected correctly. ? w hen lubricant such as oil is attached to the tip of the driver, the driv er will fall off, with a risk of injury towards the workers. usage ? please select the load within the rated range. doing so may result in damage, malfunction, or failure. ? please use the power of the rated frequency. it may cause malfunction, failure, or risk of burnout. ? install g3rv according to instructions mounting on page 23. if you install in the wrong direction, abnormal heat is generated, and may lead to short-circuiting or burning the output element. ? g3rv is an ssr that generates heat. pleas e observe the ambient temperature setting range of g3rv. if installing in an enclosed s pace, set a fan, and ventilate. ? when mounting g3rv to din rail, firmly fit it into the groove. if it is not properly installed, there is a risk of it falling. wiring ? for the current to be applied, make sure a wire size with margin is used. otherwise, excessive heat generated by the wires may cause burning . ? do not attempt to use the wire if the coat is torn. not doing so may result in electric shock. ? always turn off the power supply before performing wiring. not doing so may cause electrical shock. ? the wires of the socket for g3rv socket should not be passed through the same duct as that be ing connected to the high-voltage power supply. otherwise, inductive noise may damage the g3rv or cause it to malfunction. push-in plus terminal block ? do not wire anything to the release holes. ? do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal block. the terminal block may be damaged . ? insert a flat-blade screwdriver into the release holes at an angle. the terminal block may be damaged if you insert the screwdriver straight in. ? do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. ? do not bend the wire past its natur al bending radius or pull on it with excessive force. doing so may cause the wire disconnection. ? do not insert more than one wire into each terminal (insertion) hole . ? to prevent wiring materials from smoking or ignition, use the wiring materials given in the following table. note: use ferrules with ul certification (r/c). disposal ? do not dis pose of the product by burning . ? do not use or store the product in the following locations. doing so may result in damage, malfunction, or deterioration of performance characteristics. ? where vibration or shock is directly transmitted to the body ? do not use the product where the socket could touch a solvent or alkaline agent. ? do not insert short bar in the hol e for wire or screw driver, it ma y cause the result of failure of pull out. if insert short bar in the hole for wire or screw driver and try to pull out, it may cause damage for short bar or socket. push-in plus terminal block 1. connecting wires to the push-in plus terminal block part names of the terminal block connecting wires with ferrules insert the ferrule straight into the terminal block until the end strikes the terminal block. connecting stranded wires use the following procedure to connect the wires to the terminal block. (1) hold a flat-blade screwdriver at an angle and insert it into the release hole. t he angle should be between 10and15. if the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole respond. (2) with the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal block. (3) remove the flat-blade screwdriver from the release hole. checking connections ? after insertion, pull gently on the wire to make sure that it will not come out (i.e., to confirm that it is held by the terminal block). ? to prevent short circuits, insert the stripped part of a s tranded wire or the conductive part of a ferrule until it is hidden inside the terminal insertion hole. (see following diagram.) recommended wire stripping length ferrules when using terminal ferrules when not using terminal 0.5 to 1.5 mm 2 /awg20 to awg16 10 mm 8 mm precautions for correct use release hole terminal (insertion) hole release hole terminal (insertion) hole ferrules (2) flat-blade screwdriver stranded wires 10 to 15 (1) (3) (2) (1) (3)
g2rv-sr/g3rv-sr 22 g2rv-sr g3rv-sr common accessories common precautions 2. r emovin g wire s from the push - i n plu s terminal block use the following procedure to remove wires from the terminal block. the same method is used to remove stranded wires and ferrules. (1) hold a flat-blade screwdriver at an angle and insert it into the release hole. (2) with the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. (3) remove the flat-blade screwdriver from the release hole. 3. r e commended ferrules and tools recommended ferrules *1. make sure that the outer diameter of the wire is smaller than the inner diameter of the insulating sleeve of the recommended ferrule. *2. make sure that the ferrule processing dimensions conform to the following figure. recommended flat-blade screwdriver use a flat-blade screwdriver to connect and remove wires. use the following flat-blade screwdriver. the following table is the manufacturer and format at the time in december 2015. screw terminal ? screw terminal ? ti ghtening torque 0.4 n m ? electric w iring use the electric wire of specified size as shown above. the stripped wire length is 8 mm. operating latching lever when operating the latching lever for g2rv-sr701/501 series, use a 2.5 mm width flat-blade screwdriver. ? applicable flat-blade screwdriver flat-blade screwdriver with parallel cutting edge: shaft diameter 2.5 mm (3.0 mm max.) ? always turn off the power supply before operating latching lever. ? return to its original state after using the latching lever. ? do not use the latching lever as a switch. ? operation durability of the latching lever is 100 times or more. ? do not keep the latching lever on for a long period of time (24 hours or more) in order to maintain the operation check function. applicable wire ferrules conduct length (mm) recommended ferrules (mm 2 ) (awg) phoenix contact product weidmuller product wago product 0.5 20 8 ai0.5-8 h0.5/14 fe-0.5-8n-wh 0.75 18 8 ai0.75-8 h0.75/14 fe-0.75-8n-gy 1 18 8 ai1-8 h1.0/14 fe-1.0-8n-rd 1.5 16 8 ai1.5-8 h1.5/14 fe-1.5-8n-bk recommended crimp tool crimpfox6 crimpfox6t-f crimpfox10s pz6 roto variocrimp4 model manufacturer xw4z-00b omron esd0.402.5 wera szf 0.42.5 phoenix contact 0.42.575 302 wiha aef.2.575 facom 210-719 wago sdi 0.42.575 weidmuller (2) 10 to 15 wire flat-blade screwdriver (1) (3) (2) (1) (3) 8 mm 2.1 mm max. 8 mm side 0.4 mm 2.5 mm dia. 2.5 mm front wired type applicable wire size stripping length stranded wires, without ferrule 0.5 to 1.5 mm 2 8 mm stranded wires, with ferrule and plastic collar 0.5 to 1.5 mm 2 8 mm stranded wires with ferrule, without plastic collar 0.5 to 1.5 mm 2 8 mm stripping length 8 mm scre w terminal shaft diameter 2.5 mm (3.0 mm max.) driver with a thick shaft cannot be used. wide flat-b lade scre w driv er parallel c utting edge flat-b lade scre w driv er
g2rv-sr/g3rv-sr 23 g2rv-sr g3rv-sr common accessories common precautions method of operation of the latching lever keep the protec tive cover open when using the latching lever. move until the latching lever clicks to the on pos ition (on state). after us ing the latching lever, in order to prevent malfunction, return the switch to contact normal position (off state), and mak e sure the protective cover is firmly closed. us ing the la tching lever example: c heck t he operation of t he relay and t he s equence circuit ? since the g3rv uses electronic components, do not allow it to fall, vibrate, or apply s hock that exceeds the criteria. doing so may result in failure, malfunction, or deterioration of performance. ? tighten s crew terminal for g3rv with a torque of 0.4 n m. it may cause short-c ircuit failure or burning. ? please use the voltage and current suitable for the input and output terminal portion of g3rv. it may cause short-c ircuit failure or burning. mounting * when five or more are installed, install with 10 mm space between each. ? if the air inlet or air outlet has a fi lter, clean the filter regularly to prevent it from clogging to ensure an efficient flow of air. ? do not place objects that may obstruct the proper ventilation fo r out side or inside the inlet or exhaust port, and in the out side vi cinity. ? a heat exchanger, if used, should be located in front of the g3 rv to ensure the efficiency of the heat exchanger. ? please observe the ambient temperature of g3rv. the rat ed cur rent of the g3rv is measured at an ambient temperature of 25c. ? the g3rv uses a semiconductor in the output element. this causes the temperature in side the control panel to increase due to heating resulting from the flow of electrical current th rough the load. t he g3rv reliability can be increased by adding a ventilation fan to the control panel to dispel this heat, thus lowering the ambient temperature of the g3rv. (it suggests that life expectancy is doubled by each 10c reduction in ambient temperature.) emi the g3rv is a class a product (for industrial environments). when used in a residential envir onment, it may cause radio interference. in such case, the user may be required to take appropriate measures. contact normal position contact operating position (on-state) close protective cover open protective cover ssr 10 mm min. 30 mm min. 80 mm min. 60 mm min. duct or other object blocking airflow vertical direction airflo w metal base ssr ssr incorrect example countermeasure 1 countermeasure 2 mounting su rface mounting su rface mounting su rface ssr duct or other object b locking airflo w recommended height of the d uct is 1/2 or less of the height of the ssr duct or other object b locking airflo w v ertical direction duct or other object b locking airflo w duct or other object b locking airflo w duct or other object b locking airflo w duct or other object b locking airflo w do not enclose the ssr in a duct of the same height. it w ill interfere with the heat dissipation of ssr. use ducts that ha v e a shallo w depth, to pro vide a sufficient v entilation area. if the ducts cannot be made lo w er, place the ssr on a metal base so that it is not s urrounded b y the du cts. height of ssr ssr inlet be aware of airflow exhaust (axial fan) ssr ssr duct or other object blocking airflow
g2rv-sr/g3rv-sr 24 g2rv-sr g3rv-sr common accessories common precautions ordering information short bars note: use for wiring to the adjacent socket. * replace the box (@) in the model number with the code for the covering color. @ color selection: r = red, s = blue, y = yellow labels separate plate plc interface unit parts for din track mounting * when mounting components to din rail, prevent sliding using end plates (model pfp-m). refer to your omron website for details on pfp-@. for g2rv-sr/g3vr-sr common accessories (order separately) appearance pitch no. of poles colors model * minimum order (quantity) maximum energizing current 6.2 mm 2 red (r), blue (s), yellow (y) pydn-6.2-020 @ 10 32 a 3 pydn-6.2-030 @ 4 pydn-6.2-040 @ 10 pydn-6.2-100 @ 20 pydn-6.2-200 @ appearance model minimum order xw5z-p2.5lb2 5 sheets (1 sheet/72 pieces) appearance model xw5z-ep12 appearance i/o classification common process connection method model for input pnp push-in p2rvc-8-i-5-1 screw p2rvc-8-i-7-1 npn push-in p2rvc-8-i-5 for output pnp push-in p2rvc-8-o-5-1 screw p2rvc-8-o-7-1 npn push-in p2rvc-8-o-5 appearance type model minimum order (quantity) din tracks 1 m pfp-100n ? 0.5 m pfp-50n end plate* pfp-m 10 spacer pfp-s
g2rv-sr/g3rv-sr 25 g2rv-sr g3rv-sr common accessories common precautions applicable cables name appearance cable length l (mm) connecting cables applicable connectors cables with loose wires p2rv-a @ c 8 i/o points 1,000 137"$ various devices 2,000 137"$ 3,000 137"$ 5,000 137"$ cables with connectors (1:4) p2rv-4- @ c 32 output points 1,000 137$ plc i/o units with mil connectors (1:4) cj1w-od232/od262, etc. 2,000 137$ 3,000 137$ 5,000 1375$ cables with connectors (1:4) p2rv-4- @ imc 32 input points 1,000 137*.$ plc i/o units with mil connectors (1:4) cj1w-id232/id262, etc. 2,000 137*.$ 3,000 137*.$ 5,000 1375*.$ cables with connectors (1:4) p2rv-4- @ ifc 32 input points 1,000 137*'$ plc i/o units with fujitsu connectors (1:4) cj1w-id231/id261, etc. 2,000 137*'$ 3,000 137*'$ 5,000 1375*'$ cables with connectors (1:1) p2rv-a @ c-omr grt1 8 output points 500 137"$0.3(35 slice i/o units (1:1) for inputs: grt1-id8-1 for outputs: grt1-od8-1 1,000 137"$0.3(35 8 input points 500 137"*$0.3(35 1,000 137"*$0.3(35 cables with connectors (1:1) p2rv-a @ c-omr nx 8 output points 500 137"$0.3/9 plc i/o units with mil connectors (1:1) for inputs: nx-id4442 for outputs: nx-od4256 1,000 137"$0.3/9 8 input points 500 137"*$0.3/9 1,000 137"*$0.3/9 end a end b device end  plc interface unit end - -  -  -  - -
g2rv-sr/g3rv-sr 26 g2rv-sr g3rv-sr common accessories common precautions schneider electric plc connecting cables p2rv- @ c-sch- @ 32 input points 500 137$4$)" schneider electric plcs with 32-point connectors (1:4) for inputs: 140 ddi 353 00 for outputs: 140 ddo 353 00 1,000 137$4$)" 2,000 137$4$)" 3,000 137$4$)" 5,000 137$4$)" 32 output points 500 137$4$)# 1,000 137$4$)# 2,000 137$4$)# 3,000 137$4$)# 5,000 137$4$)# 16 input points 500 137$4$)$ schneider electric plcs with 16-point connectors (1:2) for inputs: bmx ddi 1602 for outputs: bmx ddo 1602 1,000 137$4$)$ 2,000 137$4$)$ 3,000 137$4$)$ 5,000 137$4$)$ 16 output points 500 137$4$)% 1,000 137$4$)% 2,000 137$4$)% 3,000 137$4$)% 5,000 137$4$)% siemens plc connecting cables p2rv- @ c-sim- @ 32 input points 500 137$4*." siemens plcs with 32-point connectors (1:4) for inputs: 6es7 321-1bl00-0aa0 for outputs: 6es7 322-1bl00-0aa0 1,000 137$4*." 2,000 137$4*." 3,000 137$4*." 5,000 137$4*." 32 output points 500 137$4*.# 1,000 137$4*.# 2,000 137$4*.# 3,000 137$4*.# 5,000 137$4*.# 16 input points 500 137$4*.$ siemens plcs with 16-point connectors (1:2) for inputs: 6es7 321-1bh02-0aa0 1,000 137$4*.$ 2,000 137$4*.$ 3,000 137$4*.$ 5,000 137$4*.$ 32 input points 500 137$4*.% siemens plcs with 32-point connectors (1:4) for inputs: 6es7 421-1bl-0aa0 for outputs: 6es7 422-1bl-0aa0 1,000 137$4*.% 2,000 137$4*.% 3,000 137$4*.% 5,000 137$4*.% 32 output points 500 137$4*.& 1,000 137$4*.& 2,000 137$4*.& 3,000 137$4*.& 5,000 137$4*.& name appearance cable length l (mm) connecting cables applicable connectors -  end a end b device end plc interface unit end -  -  -  - 
g2rv-sr/g3rv-sr 27 g2rv-sr g3rv-sr common accessories common precautions ratings / characteristics electrical schematic input p2rvc-8-i- @-1 (pnp) p2rvc-8-i-5 (npn) output p2rvc-8-o- @-1 (pnp) p2rvc-8-o-5 (npn) plc interface unit rated voltage 30 vac/dc rated current 0.5 a/poles, 2 a/unit ambient operating temperature ? 40 to 55c 1....................8 14 11 1 2 3 4 5 6 7 8 9 10 1....................8 14 11 1 2 3 4 5 6 7 8 9 10 1....................8 a2 a1 1 2 3 4 5 6 7 8 9 10 1....................8 a2 a1 1 2 3 4 5 6 7 8 9 10
g2rv-sr/g3rv-sr 28 g2rv-sr g3rv-sr common accessories common precautions dimensions (unit: mm) plc interface unit 12.68 67.16 29 49.60 76.20 push-i n p2rvc-8-i-5(-1) p2rvc-8-o-5(-1) 12.68 67.16 29 49.60 76.20 screw p2rvc-8-i-7-1 p2rvc-8-o-7-1
g2rv-sr/g3rv-sr 29 g2rv-sr g3rv-sr common accessories common precautions dimensions (unit: mm) short bars separate plate parts for din track mounting refer to your omron website for details on the pfp- @ . (except for plc interface unit) common accessories 2 1.20 l 9 14 6.20 note: use the short bars for crossover wiring within one socket or between sockets. * replace the box (@ ) in the model number with the code for the covering color. pitch no. of poles l (length) colors model * maximum carry current 6.2 mm 2 12.4 red (r) blue (s) yellow (y) pydn-6.2-020 @ 32 a 3 18.6 pydn-6.2-030 @ 4 24.8 pydn-6.2-040 @ 10 62 pydn-6.2-100 @ 20 124 pydn-6.2-200 @ pydn-6.2- @@ (6.2 mm) 12 63 56 xw5z-ep12
terms and conditions of sale 1. offer; acceptance . these terms and conditions (these "terms ") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "products ") by omron electronics llc and its subsidiary companies (?omron ?). omron objects to any terms or conditions proposed in buyer?s purchase order or other documents which are inconsistent with, or in addition to, these terms. 2. prices; payment terms. all prices stated are current, subject to change with- out notice by omron. omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. payments for products are due net 30 days unless otherwise stated in the invoice. 3. discounts. cash discounts, if any, will apply only on the net amount of invoices sent to buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to omron?s payment terms and (ii) buyer has no past due amounts. 4. interest. omron, at its option, may charge buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. orders . omron will accept no order less than $200 net billing. 6. governmental approvals. buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the impor- tation or sale of the products. 7. taxes . all taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on omron or required to be collected directly or indirectly by omron for the manufacture, production, sale, delivery, importa- tion, consumption or use of the products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by buyer to omron. 8. financial. if the financial position of buyer at any time becomes unsatisfactory to omron, omron reserves the right to stop shipments or require satisfactory security or payment in advance. if buyer fails to make payment or otherwise comply with these terms or any related agreement, omron may (without liabil- ity and in addition to other remedies) cancel any unshipped portion of prod- ucts sold hereunder and stop any products in transit until buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by buyer. buyer shall in any event remain liable for all unpaid accounts. 9. cancellation; etc. orders are not subject to rescheduling or cancellation unless buyer indemnifies omron against all related costs or expenses. 10. force majeure . omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. shipping; delivery. unless otherwise expressly agreed in writing by omron: a. shipments shall be by a carrier selected by omron; omron will not drop ship except in ?break down? situations. b. such carrier shall act as the agent of buyer and delivery to such carrier shall constitute delivery to buyer; c. all sales and shipments of products shall be fob shipping point (unless oth- erwise stated in writing by omron), at which point title and risk of loss shall pass from omron to buyer; provided that omron shall retain a security inter- est in the products until the full purchase price is paid; d. delivery and shipping dates are estimates only; and e. omron will package products as it deems proper for protection against nor- mal handling and extra charges apply to special conditions. 12. claims. any claim by buyer against omron for shortage or damage to the products occurring before delivery to the carrier must be presented in writing to omron within 30 days of receipt of shipment and include the original trans- portation bill signed by the carrier noting that the carrier received the products from omron in the condition claimed. 13. warranties . (a) exclusive warranty . omron?s exclusive warranty is that the products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by omron (or such other period expressed in writing by omron). omron disclaims all other warranties, express or implied. (b) limitations . omron makes no warranty or representation, express or implied, about non-infringement, merchantabil- ity or fitness for a particular purpose of the pro ducts. buyer acknowledges that it alone has determined that the products will suitably meet the requirements of their intended use. omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the products or oth- erwise of any intellectual property right. (c) buyer remedy . omron?s sole obli- gation hereunder shall be, at omron?s election, to (i) replace (in the form originally shipped with buyer responsible for labor charges for removal or replacement thereof) the non-complying product, (ii) repair the non-complying product, or (iii) repay or credit buyer an amount equal to the purchase price of the non-complying product; provided that in no event shall omron be responsi- ble for warranty, repair, indemnity or any other claims or expenses regarding the products unless omron?s analysis confirms that the products were prop- erly handled, stored, installed and maintained and not subject to contamina- tion, abuse, misuse or inappropriate modification. return of any products by buyer must be approved in writing by omron before shipment. omron compa- nies shall not be liable for the suitability or unsuitability or the results from the use of products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environ- ments. any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. see http:// www.omron247.com or contact your omron representative for pub- lished information. 14. limitation on liability; etc . omron companies shall not be liable for special, indirect, incidental, or consequential damages, loss of profits or production or commercial loss in any way connected with the products, whether such claim is based in contract, warranty, negligence or strict liability. further, in no event shall liability of omron companies exceed the individual price of the product on which liability is asserted. 15. indemnities . buyer shall indemnify and hold harmless omron companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, inves- tigation, litigation or proceeding (whether or not omron is a party) which arises or is alleged to arise from buyer's acts or omissions under these terms or in any way with respect to the products. without limiting the foregoing, buyer (at its own expense) shall indemnify and hold harmless omron and defend or set- tle any action brought against such companies to the extent based on a claim that any product made to buyer specifications infringed intellectual property rights of another party. 16. property; confidentiality. any intellectual property in the products is the exclu- sive property of omron companies and buyer shall not attempt to duplicate it in any way without the written permission of omron. notwithstanding any charges to buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of omron. all information and materials supplied by omron to buyer relating to the products are confidential and proprietary, and buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 17. export controls. buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to ?forbidden? or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 18. miscellaneous . (a) waiver . no failure or delay by omron in exercising any right and no course of dealing between buyer and omron shall operate as a waiver of rights by omron. (b) assignment . buyer may not assign its rights hereunder without omron's written consent. (c) law. these terms are governed by the law of the jurisdiction of the home office of the omron company from which buyer is purchasing the products (without regard to conflict of law princi- ples). (d) amendment . these terms constitute the entire agreement between buyer and omron relating to the products, and no provision may be changed or waived unless in writing signed by the parties. (e) severability . if any provi- sion hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) setoff . buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) definitions . as used herein, ?including ? means ?including without limitation?; and ?omron compa- nies ? (or similar words) mean omron corporation and any direct or indirect subsidiary or affiliate thereof. certain precautions on specifications and use 1. suitability of use . omron companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the product in the buyer?s application or use of the product. at buyer?s request, omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the product. this information by itself is not sufficient for a complete determination of the suitability of the prod- uct in combination with the end product, machine, system, or other application or use. buyer shall be solely responsible for determining appropriateness of the particular product with respect to buyer?s application, product or system. buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) use in consumer products or any use in significant quantities. (iii) energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equip- ment, and installations subject to separate industry or government regulations. (iv) systems, machines and equipment that could present a risk to life or prop- erty. please know and observe all prohibitions of use applicable to this prod- uct. never use the product for an application involving serious risk to life or property or in large quantities without ensuring that the system as a whole has been designed to address the risks, and that the omron?s pro duct is prop- erly rated and installed for the intended use within the overall equipment or system. 2. programmable products. omron companies shall not be responsible for the user?s programming of a programmable product, or any consequence thereof. 3. performance data . data presented in omron company websites, catalogs and other materials is provided as a guide for the user in determining suitabil- ity and does not constitute a warranty. it may represent the result of omron?s test conditions, and the user must correlate it to actual application require- ments. actual performance is subject to the omron?s warranty and limitations of liability. 4. change in specifications . product specifications and accessories may be changed at any time based on improvements and other reasons. it is our prac- tice to change part numbers when published ratings or features are changed, or when significant construction changes are made. however, some specifica- tions of the product may be changed without any notice. when in doubt, spe- cial part numbers may be assigned to fix or establish key specifications for your application. please consult with your omron?s representative at any time to confirm actual specifications of purchased product. 5. errors and omissions. information presented by omron companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
omron canada, inc. ? head office toronto, on, canada ? 416.286.6465 ? 866.986.6766 ? www.omron247.com omron electronics de mexico ? head office mxico df ? 52. 55.59.01.43.00 ? 01-800-226-6766 ? mela@omron.com omron electronics de mexico ? sales office apodaca, n.l. ? 52.81.11.56.99.20 ? 01-800-226-6766 ? mela@omron.com omron eletr?nica do brasil ltda ? head office s?o paulo, sp, brasil ? 55.11.2101.6300 ? www.omron.com.br omron argentina ? sales office cono sur ? 54.11.4783.5300 omron chile ? sales office santiago ? 56.9.9917.3920 other omron latin america sales 54.11.4783.5300 authorized distributor: j285i-e-01 06/16 note: specifications are subject to change. ? 2016 omron. all rights reserved. printed in u.s.a. printed on recycled paper. omron automation americas headquarters ? chicago, il usa ? 847.843.7900 ? 800.556.6766 ? www.omron247.com omron europe b.v. ? wegalaan 67-69, nl-2132 jd, hoofddorp, the netherlands. ? +31 (0) 23 568 13 00 ? www.industrial.omron.eu controllers & i/o ? machine automation controllers (mac) ? motion controllers ? programmable logic controllers (plc) ? temperature controllers ? remote i/o robotics ? industrial robots ? mobile robots operator interfaces ? human machine interface (hmi) motion & drives ? machine automation controllers (mac) ? motion controllers ? servo systems ? frequency inverters vision, measurement & identification ? vision sensors & systems ? measurement sensors ? auto identification systems sensing ? photoelectric sensors ? fiber-optic sensors ? proximity sensors ? rotary encoders ? ultrasonic sensors safety ? safety light curtains ? safety laser scanners ? programmable safety systems ? safety mats and edges ? safety door switches ? emergency stop devices ? safety switches & operator controls ? safety monitoring/force-guided relays control components ? power supplies ? timers ? counters ? programmable relays ? digital panel meters ? monitoring products switches & relays ? limit switches ? pushbutton switches ? electromechanical relays ? solid state relays software ? programming & configuration ? runtime


▲Up To Search▲   

 
Price & Availability of G2RV-SR500-APDC12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X